- Home
- Laboratory
- Centrifuges
- Ohaus Frontier™ FC5830R Multi Pro Centrifuges
Product Description
The Ohaus Frontier™ 5000 Series Multi-Pro Centrifuges are designed for universal use in multiple applications in research, industrial, and clinical laboratories and can be combined with a wide range of rotors and accessories for customized use. The intuitive design of the centrifuges & accessories enable easy access to parameter settings, and quick rotation between applications. They feature automatic rotor recognition and backlit LCD. The performance of these centrifuges is propelled by German engineering, and high-quality components for reliable use. They are constructed of chemical-resistant stainless steel to ensure durability in lab use. Design features include ten acceleration and deceleration rates and selection of running time from 10 s to 99 h 59 min or continuous, quick spin. These Frontier™ 5000 Series centrifuges are equipped with protective features, including automatic over-speed protection, imbalance detection and a self-diagnostic system to ensure reliable use and operator safety.
This FC5830R model is a high-speed multipurpose refrigerated centrifuge. It is compatible with up to 11 optional rotors and 56 accessories and offers capacities from microliter to 6 x 250 mL. Improved sample processing through-put is provided with additional rotor for blood collection tubes and standard conical tubes. The CFC-free refrigeration system provides a temperature range of -20 to 40°C. This refrigerated unit has a pre-cooling program to quickly reach the desired temperatures, sample temperature indication and standstill cooling. Microtubes can be spun up to 30,000 rpm while 50 mL tubes can be spun up to 21,000 rpm. The unit measures 20.4" l x 28.5" w x 16.3" h (519 x 723 x 413 mm) and has a weight of 200.2 lb (91 kg) without a rotor.
Applications:Centrifugal Separation, General Sample Preparation, Cell Pelleting, Protein Separation, Nucleic Acid Separation, Cell Concentrating, Chemical Separation, Diagnostics, Environmental Sample Preparation, Blood Sample Processing.
Literature available: Frontier™ 5000 Multi-Pro Summary Sheet and Comparison Guide, FC5714 Rotor Compatibility Table , Ohaus Centrifuge Comparison Guide, Frontier™ 5000 Rotor Guide.
Accessories: 4 x 290 mL, ID, Swing Out Rotor (item # H-30314820), 6 x 250 mL FB, ID, Angle Rotor (item # H-30314821), 2 x 3MTP, w/bucket ID Swing Out Rotor (item # H-30314824), 6 x 85 mL RB, ID, Angle Rotor (item # H-30314826), 4 x 85 mL RB, ID, Hi Angle Rotor (item # H-30314827), 10 x 50 mL FA, ID, Angle Rotor (item # H-30314829), 6 x 50 mL RB, ID, Hi Angle Rotor (item # H-30314831), 30 x 15 mL RB/FA, ID, Angle Rotor (item # H-30314832), 20 x 10 mL RB, ID, Hi Angle Rotor (item # H-30314833), 30 x 1.5/2.0 mL, ID, Sealable Angle Rotor (item # H-30314836), 12 x 1.5/2.0 mL, ID, Angle Rotor (item # H-30314839).
Frontier™ 5000 Series Multi-Pro Centrifuge Comparison:
Model | Speed Range | Temp. Range | Max. g-Force | Swing-Out Rotor Max. Capacity | Angle Rotor Max. Capacity |
FC5714 | 200 rpm - 14,000 rpm | Air Cooled | 18,624 g | 4 x 200 mL | 30 x 15 mL |
FC5718 | 200 rpm - 18,000 rpm | Air Cooled | 23,542 g | 4 x 200 mL | 6 x 85 mL |
FC5718R | 200 rpm - 18,000 rpm | -20° to 40° C | 23,542 g | 4 x 200 mL | 6 x 85 mL |
FC5720R | 200 rpm - 20,000 rpm | -20° to 40° C | 38,007 g | 4 x 200 mL | 6 x 85 mL |
FC5816 | 200 rpm - 15,000 rpm | Air Cooled | 21,379 g | 4 x 290 mL | 6 x 250 mL |
FC5816R | 200 rpm - 16,000 rpm | -20° to 40° C | 24,325 g | 4 x 290 mL | 6 x 250 mL |
FC5830R | 200 rpm - 30,000 rpm | -20° to 40° C | 65,395 g | 4 x 290 mL | 6 x 250 mL |
FC5916 | 200 rpm - 16,000 rpm | Air Cooled | 24,325 g | 4 x 750 mL | 4 x 500 mL |
FC5916R | 200 rpm - 16,000 rpm | -20° to 40° C | 26,331 g | 4 x 750mL | 4 x 500 mL |
FC5917RF | 200 rpm - 16,010 rpm | -20° to 40° C | 26,361 g | 4 x 1 L | 4 x 500 mL |
![]() |
WARNING: OHAUS products can expose you to chemicals including the chemicals listed in this Table, which are known to the State of California to cause cancer and/or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. These and other Proposition 65 chemicals may be present only in residual amounts, or contained internally in OHAUS equipment, or encapsulated in another material where exposure is unlikely or negligible. This warning is being provided out of an abundance of caution. |
Product Videos
Frontier 5000 Multi Pro Centrifuges are designed for universal use in research, industrial & clinical laboratories, and can be combined with our rotors & accessories for customized use in specific applications. Learn more at www.ohaus.com
-
OHAUS Frontier...Frontier 5000 Multi Pro Centrifuges are designed for universal...